Home / Codes / ASME A17.7 / CSA B44.7
Performance-Based Safety Code for Elevators and Escalators
An alternative path to A17.1: new designs are approved by proving they meet safety performance targets through risk assessment, rather than meeting prescriptive rules.
Check which edition your jurisdiction has adopted before you work to it.
Who Uses It
Manufacturers bringing new technology to market, certifying organizations and jurisdictions.
How It's Organized
| Global essential safety requirements | The safety targets a design must meet |
|---|---|
| Risk assessment | How a design is evaluated and certified |
Related
Safety Code for Elevators and Escalators
The core code for new elevator, escalator, moving walk, dumbwaiter and material lift installations, and for the…
Guide for Inspection of Elevators, Escalators, and Moving Walks
The inspector's companion to A17.1: what to look at, how to check it and what to test during acceptance and periodic…
Safety Code for Existing Elevators and Escalators
Minimum safety requirements for elevators and escalators already in service. Used by jurisdictions to bring older…
Guide for Emergency Personnel
How firefighters and emergency crews safely evacuate passengers from stalled elevators and…
Elevator and Escalator Electrical Equipment
Construction, testing and certification requirements for elevator and escalator electrical equipment: controllers,…
Standard for Elevator Suspension, Compensation, and Governor Systems
Requirements for suspension and governor means: steel wire rope, aramid fiber rope and noncircular elastomeric-coated…
Standard for Wind Turbine Tower Elevators
Requirements for elevators installed inside wind turbine…